Appliance Repair Biltmore Forest North Carolina

ASI Authorized Service Inc Rated out of 5 stars based on customer reviews

We serviced a
MAYTAG WASHER
Model MVW7232HW0
Near Biltmore Forest, NC 28803
Kari
Job Details: 12/17/2024
Installed parts unit checks ok
We serviced a
MAYTAG WASHER
Model MVW7232HW0
Near Biltmore Forest, NC 28803
Kari
Job Details: 12/13/2024
"Took quick pics, found unit doa. And clothes stuck inside. Took top off and let customer get clothes out. Checked outlet and found 120v and correct polarity. Took console off and found no indication light on acu. Found 120v into control but no power outputted to ui. Ohms checked all components from control and found all loads check ok. Will need acu for repair. Rescheduled for Tuesday AM; ordrng 1 J13 (Job code)"
We serviced a
MAYTAG WASHER
Model MVW7232HW0
Near Biltmore Forest, NC 28803
Kari
Job Details: 12/13/2024
"Took quick pics, found unit doa. And clothes stuck inside. Took top off and let customer get clothes out. Checked outlet and found 120v and correct polarity. Took console off and found no indication light on acu. Found 120v into control but no power outputted to ui. Ohms checked all components from control and found all loads check ok. Will need acu for repair. Rescheduled for Tuesday AM; ordrng 1 J13 (Job code)"
We serviced a
JENN-AIR ICE MACHINE
Model JUIFN15HX01
Near Biltmore Forest, NC 28803
Brian
Job Details: 10/23/2024
"Customer showed me where granite countertop is a bit warm above unit. Tested unit and found condenser fan operating normally. All other functions ok with unit. Explained to customer that the unit is functioning as designed and that the only other option would be to remove some of the cabinetry behind drawers next to unit to allow more airflow to unit. I recommend customer keep unit off, when not in use to cut down on some of the run time. Customer understood. At this time, all operations ok with no leaks detected."
We serviced a
WHIRLPOOL ICE MACHINE
Model WUI75X15HZ01
Near Biltmore Forest, NC 28803
Brian
Job Details: 08/23/2024
"Complaint is that ice is wet and soupy throughout the day. I tested and found heater ok and bin thermistor ok. In diagnostic I found water reservoir not filling all the way. Compressor fan ok and good frost pattern. Replaced Circulation pump (W11542867) and tested again. Found all operations ok at this time, with no leaks detected. Did not move unit."